Henan Enbuess Composite Materials Co., Ltd. is one of the leading manufacturers and suppliers of 807 thermally broken aluminium fire window in China. We are committed to providing high quality customized service for global clients. If you're going to buy high strength 807 thermally broken aluminium fire window made in China, welcome to get free sample from our factory.

Three letters, three different products, and the gap between them is where projects fail inspection:
- E (integrity). No flame or hot gas through the assembly for the rated time. Standard fire windows, and the E60 rating most suppliers quote.
- EW (integrity + radiation). Adds a limit on radiant heat through the glass - relevant where people evacuate past the window.
- EI (integrity + insulation). Adds a limit on the temperature rise on the unexposed face. This is what Class A means in the Chinese fire-glass classification, and what A1.50h states: 90 minutes at Class A.
An E-rated window in an EI compartment is a specification error that only surfaces at handover. The 807 exists so that the window can match the wall it sits in - and it does it without the steel.

Our finished doors and windows bring a premium, smooth matte or gloss finish to residential renovation projects, using eco-friendly water-based polyurethane paint with full RAL color matching. The surface is scratch-resistant and UV-stable, so it stays looking new long after installation. Homeowners appreciate the uniform, high-end appearance that complements both modern and traditional interior and exterior designs.
Our foreign trade mainly exports door and window profiles.
You can buy only our composite door and window profiles and assemble them into finished windows in your own country.
This helps you save a lot on shipping costs.
Our MOQ is generally 2000 meters and above.


Every window and door is built on a systematically engineered profile system designed for reliable water tightness, air tightness, wind resistance and sound insulation. High-quality branded resins, glass fiber and coatings are used throughout, and full surface pre-treatment ensures the paint adheres tightly and won't crack or peel. Precision manufacturing means tight tolerances and clean, consistent finishes that installers love to work with.
We stand behind our products with clear warranty terms and fast customer support. If your homeowner has questions or issues after installation, we respond quickly with troubleshooting guidance or replacement parts, helping you deliver a worry-free renovation experience and protect your referral reputation.


GRFPU Pultrusion Process
GRFPU material as one thermoset composites are built up by polyurethane resin as a matrix (about 20%) in combination with continuous fiber-reinforced (about 80%) materials, which is produced through a proprietary injection pultrusion molding process into a specific cross-sectional profile.
1. Reinforced fiberglass (80% Glass fiberglass Rovings)
2. Measuring pump
3. Guide plate
4. MDI storage tank
5. PPG storage tank
6. Static mixer
7. Injection die
8. Heated pultrusion die
9. Crawler pulling device
10. Cut off Saw
11. Finished profile

Steel is the default answer for A-class fire windows, and it works - until the building is in use:
- Cold bridge. A steel frame in a conditioned corridor is the coldest surface in the room; condensation, mould at the reveal, and rust starting at exactly the point where the paint failed.
- Corrosion at the bottom rail, where cleaning water sits. Once the section is perforated, the certificate describes something that no longer exists.
- Repainting cycles, which mean access equipment and a window out of service.
- Weight, which drives the fixing detail into lightweight walls.
The 807 replaces the steel section with a thermally broken aluminium profile filled with polyurethane: the structural behaviour of aluminium, the thermal behaviour of the PU core, and no cold bridge through the frame - so the frame is not the reason the reveal goes black.
Fire performance is a property of the tested build, not of the frame alone. The 807 is supplied with the glazing configurations below, and the rating applies to those combinations:
- 5Low-E + 12A + 23/25 Class B insulated fire glass
- 5Low-E + 12A + 32/35 Class A insulated fire glass
- 5Low-E + 12Ar + 5 + 12Ar + 23/25 Low-E Class B fire glass
Glazing range is 41–48 mm, which is what allows the assembly to carry an insulating unit rather than a single fire pane. If your specification calls for a different glass build, tell us at enquiry: the answer is either "covered" or "needs re-testing", and we will say which.
Fire compartment façades and internal walls where the window has to hold for 90 minutes and keep the safe side survivable: escape corridors, stair enclosures, corridor vision panels, plant room walls, and atrium separation lines. Inward and outward opening versions are both available, so the same section works on the façade and on the corridor side.
Not every buyer wants a finished window. A project team needs units delivered glazed, labelled by opening and packed for site. A window fabricator needs profiles delivered cut to length, with drainage and hardware openings already punched, so the line can assemble against its own glass and hardware. Both come off the same dies.
| Route | Finished units | Profiles for fabrication |
| Who it suits | Contractors and developers with an opening schedule | Window and door fabricators with their own assembly line |
| What arrives | Assembled, glazed, labelled per opening, packed for site | Cut-to-length profiles, punched, with the tested glazing specification |
| What you do | Install | Assemble, glaze, fit hardware to your own supply chain |
One condition applies to the fire-rated build, and we state it plainly: A1.50h belongs to the tested assembly, not to the profile. If you fabricate the 807 yourself, the glass build, the beading and the seal must match the tested configuration. We issue that specification with the order and tell you when a proposed build falls outside it - where it does, we quote finished units instead.
| Spec | 807 | 758 |
| Fire performance | A1.50h (Class A) - integrity + insulation | E60(o) - integrity only |
| Frame U-value | 1.4–2.0 W/(m²·K) | 1.3–1.6 W/(m²·K) |
| Glazing range | 41–48 mm | 22–44 mm |
| Opening | Inward / outward | Inward |
| Choose it when | The compartment requires EI or Class A | The compartment only requires E |
If the fire strategy says E, the 758 is cheaper and thermally slightly better. If it says EI or Class A, only the 807 is the correct answer - and no amount of glass upgrading turns an E window into an EI one.
| Item | Parameter |
| Model | EBS 807 Thermally Broken Aluminium Fire Window |
| Type | Energy-saving fireproof window |
| Frame | Thermally broken aluminium with polyurethane core |
| Fire integrity | A1.50h (Class A) |
| Fire insulation | A1.50h (Class A) |
| Thermal insulation | 1.4–2.0 W/(m²·K) |
| Glazing range | 41–48 mm |
| Glazing option | 5Low-E+12A+23/25 Class B; 5Low-E+12A+32/35 Class A; 5Low-E+12Ar+5+12Ar+23/25 Low-E Class B |
| Air tightness | Class 8 |
| Water tightness | Class 6 |
| Wind load resistance | Class 9 |
| Sound insulation | Class 3–4 |
| Opening mechanism | Inward / outward |
| Supply options | Finished units / cut-to-length profiles |
| Origin | Henan, China · Brand: Enbuess |
A fire window is only as good as its fixing. We issue the frame with the anchor pattern for your wall type and the permissible gap range at the head and jambs, because that gap is what the inspector measures. Where the window sits in a fire-rated façade system, the interface detail is supplied with the section so the compartment line is not broken by a site-made shim.
Material Property
Corrosion Resistance Performance

Aluminum/Polyurethane



5% HCL
(hydrochloric acid)
for 66 hours

10% NaOH
(natrium hydroxydatum)
for 24 hours

Na₂CO₃
(natrium carbonicum)
for 106 hours
Performance Testing

SOUND INSULATION
Sound insulation, quiet living
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.

HIGH STRUCTURAL STRENGTH
High strength, strong and durable
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.

CORROSION & AGING RESISTANCE
Corrosion and moisture resistant
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.

FIRE RETARDANT
Fire retardant safety performance
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.

EXCELLENT WEATHER RESISTANCE
Weather & aging resistant
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.

LOW CARBON
Low carbon, energy-efficient
We provide official factory warranty. Under normal installation and use, non-artificial quality problems are eligible for maintenance and replacement services.
Q: Does A1.50h mean 90 minutes?
A: Yes - 1.50 h at Class A, which covers both integrity and insulation. If your specification is written as EI 90, that is the equivalent requirement; if it is written as E 90, the 807 exceeds it.
Q: Can I use my own fire glass?
A: Only if that build is part of the tested assembly, or if you accept re-testing. Send the glass specification and we will tell you which case applies before you commit.
Q: Is the frame actually thermally broken?
A: Yes - the aluminium is broken by a polyurethane core, which is why the frame U-value sits at 1.4–2.0 instead of the 2.5–3.5 of a standard aluminium section. It also means the inner face stays warmer, so the reveal does not become the mould line.
Q: Inward or outward opening?
A: Both. Outward is more common on façades, inward on corridors where the leaf must not obstruct evacuation. Confirm at order so the hardware and the rebate are set correctly.
Q: Can we buy profiles and fabricate the windows ourselves?
A: Yes, subject to the condition above: the rating is tied to the tested assembly. We supply cut-to-length profiles with the glazing and beading specification, and confirm in writing whether your build matches it before you order.

Tell us the span and what it has to carry
Send the outside diameter you are using now, or the span and the load. We will come back with a size recommendation, the deflection figures, and a price. If the answer is that steel or stainless is the better call for this job, we will say that.
Hot Tags: 807 thermally broken aluminium fire window, China 807 thermally broken aluminium fire window manufacturers, suppliers, factory