An FRP louver that lets the air through, keeps the rain out, and does not need to be repainted in a chemical atmosphere
Composite louver system for industrial facades, mechanical rooms, and coastal buildings. Drainage-designed blade geometry sheds rain without blow-back; integral color; corrosion-proof in chemical, acid, and salt-spray environments.
Request louver layout quote Download spec sheet (PDF)
Free area (typical)
{{50}}+%
Wind-driven rain test passed
{{2.5}} m/s
Thermal conductivity
0.34 W/mK
Service life
25 yr
What the buyer is trying to solve
Why the page exists.
The buyers who arrive at this page are plant ventilation engineers, mechanical-room designers, and facade specifiers who need a corrosion-proof louver for an industrial building. The existing aluminum louver has pitted at the welds; the existing galvanized steel louver has rusted at the mullion; the existing painted aluminum louver is on its third paint cycle. They want a louver that lets the air through at the published free-area ratio, sheds rain under wind-driven conditions, and survives the atmosphere for 25 years without recoating.
Four use cases where FRP louver is the right answer
Chemical-plant facades
Acid mist plume around the building envelope; aluminum pits, steel rusts.
01
Coastal / salt-spray buildings
Salt-spray corrosion on aluminum and galvanized; FRP shrugs it off.
02
Wastewater / desalination
Chlorine contact area; ventilation louver must not corrode.
03
Mechanical-room intake
Equipment-room ventilation louver; corrosion-proof over equipment life.
04
Blade families
Choose the blade family by your free-area and rain-shed requirement.
L-D standard drainable
Standard drainable blade, {{3:12}} ratio, integral drainage path. ~ {{50}}% free area.
01
L-HD heavy drainable
Heavy drainable blade, {{4:12}} ratio, deeper drainage channel. ~ {{45}}% free area; better rain shedding.
02
L-NS non-sightline
Non-sightline blade for plant office or control-room visibility restriction. ~ {{40}}% free area.
03
L-AC acoustic
Acoustic-infilled blade for plant noise control. ~ {{30}}% free area; STC {{30–35}}.
04
L-FS fixed station
Fixed-station louver for ventilation cabinet and equipment-room application. Custom geometry.
05
Specifications
|
Blade family |
Drainable L-D, L-HD; non-sightline L-NS; acoustic L-AC; fixed station L-FS |
|
Free area |
{{30–50}}% depending on blade family |
|
Blade thickness |
{{2.5–4.0}} mm depending on blade depth |
|
Mullion |
Pultruded FRP channel, {{50 × 25}} mm standard |
|
Frame |
Pultruded FRP channel, {{80 × 40}} mm standard |
|
Wind-driven rain test |
{{2.5}} m/s wind, no water ingress into the {{2nd}} water penetration class per AMCA 500-L |
|
Standard sizes |
Up to {{3}} m wide × {{4}} m tall per panel; multi-panel for larger openings |
|
Mounting |
Surface-mount frame; recessed frame on request |
|
Anchor |
Stainless A4 self-drilling bolts through frame to existing wall |
|
Insect screen |
Optional stainless or aluminum mesh, {{1.5 × 1.5}} mm opening |
|
Bird screen |
Optional stainless mesh, {{12.5 × 12.5}} mm opening |
|
Resin system |
Vinyl-ester (FR); isophthalic (economy) |
|
UV package |
UV-9 inhibitor integral + UV-stable topcoat on visible surfaces |
|
Fire performance |
ASTM E84 Class A on request |
|
Volume resistivity |
> 10⁸ Ω·cm (non-conductive) |
|
Color |
Standard grey RAL {{7035}}; other RALs on request |
|
Design life |
{{25}} years in chemical atmosphere |
When not to specify FRP louver
Cases where aluminum or steel remains correct.
Three cases where we redirect
- Architectural metal finish required. If the owner has specified a polished or anodized aluminum visual in the procurement spec, FRP cannot match it visually. Specify the metal and budget for the paint cycle.
- Very large opening (> {{6}} m² single panel). FRP louver panels are stiff enough up to {{3 × 4}} m. Beyond that, structural framing must be re-engineered or a different supplier is needed.
- Live fire / smoke exhaust application. FRP is not the standard material for fire-rated smoke exhaust louvers; a fire-rated metal louver with motor is the right product family. We can name suppliers.
Material comparison
|
Property |
Anodized aluminum louver |
Galvanized steel louver |
Enbuss FRP louver |
|
Mass per m² |
~ {{12}} kg/m² |
~ {{25}} kg/m² |
~ {{6}} kg/m² |
|
Free area |
{{45–50}}% |
{{45–50}}% |
{{40–50}}% |
|
Coating cycle |
Anodize {{10–15}} yr |
{{24–36}} months |
None |
|
Coastal service life |
{{10–15}} yr (pitting) |
{{5–10}} yr (rust) |
{{25}}+ yr |
|
Galvanic with aluminum cladding |
No (same material) |
Yes - needs isolation |
No |
|
Wind-driven rain performance |
Standard drainable |
Standard drainable |
Equivalent |
|
25-yr cost (coastal site) |
Some replacement |
2 recoat cycles + some replacement |
No replacement |
Customization & OEM
Building contractors and louver installers typically need a panel sized to the wall opening with the project-specific hole pattern. We supply the louver as a complete panel with frame, mullions, blades, screens, and anchor pattern. First article {{6–8}} weeks; repeat {{3–4}} weeks.
Frequently asked questions
What is the typical lead time for a 50-panel louver order?
From PO to first delivery, typically {{8–10}} weeks for standard L-D louver in grey RAL {{7035}}. Custom blade or color adds {{2}} weeks.
Does the louver pass the AMCAAC 500-L wind-driven rain test?
The drainable blade family passes Class A wind-driven rain at {{2.5}} m/s wind speed per AMCA 500-L. Heavier-rain applications verified on first article. Class C (hurricane-zone) configurations available on request.
Is the louver AMCA-certified?
AMCA ratings published for water penetration, airflow, and pressure drop are project-specific; we can publish ratings for the specific panel geometry on first article.
Can the louver be supplied with a removable insect screen?
Yes. Stainless or aluminum mesh in {{1.5 × 1.5}} mm opening, mounted on a removable frame for cleaning access.
How is the louver installed?
Surface-mount or recessed-mount frame with stainless A4 anchor bolts through the existing wall. Installation per the project drawing; we supply the installation manual with each shipment.
Can the louver be supplied in custom RAL color?
Yes, full RAL range. Standard grey RAL {{7035}} for fast delivery; other RALs add {{2}} weeks.
How is the louver inspected in service?
Visual at annual walk-around; look for surface damage, UV chalking, or impact cracks. Insect screen should be cleaned annually. Inspection interval typically annual.
What documentation comes with each shipment?
Per shipment: dimensional inspection, resin lot certificate, ASTM E84 (if specified), installation drawing, anchor BOM.

Send a wall opening layout
Send the wall opening dimensions, the free-area target, the wind-driven rain class, and the atmospheric exposure. We return a louver panel BOM, a fixed quote, and the AMCA reference data.