A pultruded basalt-FRP composite bracket for PV module mounting. Engineered for coastal, offshore, alkali-soil, and high-humidity sites where conventional galvanized-steel brackets degrade before the project finance closes out.
Request project quote Download spec sheet (PDF)
BASALT PV BRACKET AT A GLANCE
Fiber reinforcement: Basalt fiber roving + mat (BFRP)
Resin system: Vinyl-ester (UV-stable)
Tensile strength: {{check published value}} MPa (ASTM D638)
Standard bracket load: {{2.4}} kN design load; up to {{4.0}} kN on request
Salt spray rating: No degradation after {{3000}} h ASTM B117
Operating temperature: −40 °C to +80 °C continuous

What the buyer is trying to solve

Why EPCs and developers arrive at this page.
The buyers who land here are solar EPCs and project developers specifying brackets for utility-scale and C&I sites in coastal, alkali-soil, or high-humidity geographies. The bracket is a small line item, but the consequence of getting it wrong is large: galvanized-steel brackets that corrode through within 8 to 12 years, leaking rust onto the module frames and forcing a tracker-and-bracket replacement inside the loan tenor. The bracket is part of the asset life.
Four site classes where basalt-FRP outperforms the standard choice
Coastal PV sites
Within 1–3 km of salt water. Conventional galvanized brackets show red rust within 5–8 years.
01
Alkali-soil sites
Inland desert and steppe sites where ground-water salts creep up through the foundation concrete.
02
Floating or near-water solar
Reservoir and canal-top arrays where humidity stays near 100 percent and water splash is constant.
03
High-UV tropical sites
Equatorial sun that chalks unprotected coatings and degrades commodity plastics within 4–6 years.
04

Specifications
Published bracket ratings are based on Enbuss type testing. Project-specific certification copies issued per purchase order. Verify with the spec sheet for your bracket series.
|
Fiber |
Basalt fiber roving + chopped-strand mat; basalt fiber is a mineral fiber derived from molten basalt, chemically inert |
|
Resin |
Vinyl-ester, UV-stable formulation; UV-9 inhibitor integral |
|
Process |
Pultrusion for constant-section profiles; hand lay-up for variable-section adapters |
|
Standard bracket load |
{{2.4}} kN design load per bracket; {{4.0}} kN heavy-duty on request |
|
Tensile strength (longitudinal) |
{{verify published value}} MPa (ASTM D638) |
|
Flexural strength |
{{verify published value}} MPa (ASTM D790) |
|
Volume resistivity |
> 10⁸ Ω·cm (non-conductive - additional UL 2703 bonding still required per project) |
|
Salt spray rating |
No measurable degradation after {{3000}} h ASTM B117 (verify on first article) |
|
UV package |
UV-9 inhibitor integral in resin + UV-stable gelcoat on exposed surfaces |
|
Operating temperature |
−40 °C to +80 °C continuous |
|
Anchor interface |
Stainless A4 M12 / M16; chemical anchor to concrete; through-bolt to steel rafter |
|
Grounding |
UL 2703-listed bonding hardware supplied as kit; bonding is electrical, not structural |
|
Design life |
25 years (utility-scale asset life) |
|
Color |
Dark grey / black standard; custom RAL on request |


When not to specify basalt-FRP brackets

Cases where the conventional choice is correct.
Three cases where we redirect you back to galvanized or aluminum
- Inland, temperate, low-corrosion sites. Standard hot-dip galvanized steel brackets are cost-correct for sites that are not coastal, not alkali, and not floating. Specifying basalt-FRP here raises capex without buying measurable life.
- Project capex ceiling is strict. Basalt-FRP brackets carry a {{20–40}} percent capex premium over galvanized steel (verify with current quote). For projects where capex-per-watt is the constraint and the asset life assumption is 15 years, the conventional choice wins.
- Standard tracker-company brackets are pre-approved. Most tracker OEMs pre-qualify specific bracket geometries and materials. If your tracker OEM has approved only galvanized steel, do not substitute without their sign-off - the tracker warranty is bigger than the bracket choice.
Material comparison
|
Property |
Hot-dip galvanized steel |
Aluminum 6005-T5 |
Enbuss basalt-FRP |
|
Mass per bracket (typical utility bracket) |
~ {{2.0}} kg |
~ {{0.7}} kg |
~ {{0.9}} kg |
|
Coastal site life (1 km from salt water) |
5–8 years (red rust) |
15–20 years (pitting) |
25+ years |
|
Alkali soil life |
8–12 years |
15–20 years |
25+ years |
|
Thermal expansion match to PV module |
Higher than module - slips under clamp |
Similar to module |
Tunable - closer to glass expansion |
|
Galvanic corrosion with aluminum module frame |
Yes - needs isolation |
No - same material |
No - different material class |
|
Capex vs galvanized baseline |
Baseline |
{{1.6}} × |
{{1.2–1.4}} × |
|
25-yr lifecycle cost (coastal site) |
Replacement at year 8 + 18 |
Some replacement at year 18 |
No replacement within asset life |
Customization & OEM
Most projects buy from the standard bracket family. Some tracker OEMs need a geometry adapted to a specific clamp pattern - we do that as a kit. Larger developers sometimes want the bracket printed with a project-specific ID for asset tracking; we do that too. First article {{6}} weeks; repeat {{3}} weeks.

Frequently asked questions
What is the typical lead time for a 50 MW order?
From PO to first delivery, typically {{8–10}} weeks for standard brackets in dark grey. Custom color or geometry adds {{2–3}} weeks. We hold forecast slots for major utility developers; ask your account engineer.
Is basalt fiber a sustainable material choice?
Basalt fiber is produced from molten basalt rock without chemical additives. It is recyclable, has no VOC emissions in production, and outlasts the assets it supports.
Can the bracket be supplied with built-in cable management?
Yes. Integrated cable channel on the underside of selected profiles; specify on RFQ. Useful for string-combiner-to-inverter runs.
Is the bracket UL 2703 listed?
Our bonding hardware kit is UL 2703 compatible. Final UL 2703 listing of the bracket-and-rail system is the responsibility of the system integrator; we provide the documentation pack for that submission.
How is the bracket inspected in service?
Visual inspection at the project annual maintenance check. Look for surface damage, UV chalking, or impact cracks. Any visible crack or fiber exposure is grounds for replacement; the bracket is non-corrosive so the failure mode is mechanical, not chemical.
Does the bracket require a separate lightning protection system?
Yes. The bracket is non-conductive, so the lightning protection path must be designed separately. We supply the bracket with a dedicated bonding point for the lightning conductor; the lightning system itself is by the project electrical engineer.
What documentation comes with each shipment?
Per shipment: dimensional inspection, resin lot certificate, ASTM B117 salt-spray summary, ASTM D638 / D790 type test reference, installation drawing, and the bonding hardware kit.
Can the bracket be cut and drilled on site?
Yes - diamond blade, dust extraction, edge sealer kit supplied. Field modification does not affect bracket life if cut edges are sealed with the kit provided.

Send a site survey and the module datasheet
Send the site soil and atmosphere class, the module brand and frame geometry, and the bracket count. We return a layout, a fixed quote, and the certification pack needed for the lender's technical advisor.